Ingersoll Rand P1IU-A9 Gebrauchs- und Pflegehandbuch Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
SPECIFICATIONS
Motor Si
ngle-Phase, Induction Motor
Power Source Single-Phase, 120V AC 60 Hz
Current 15.0 A
Tank Capacity 4 gal. (15.1 l)
Maximum Pressure 135 PSI (9.3 bar)
Free Air Delivery
Lubrication Oil
PREPARATION FOR USE
SELECT
ING A LOCATION___________________________
GENERAL. Select a clean, dry, well-lighted area with plenty of
space for proper cooling air flow and accessibility. Locate the unit
on a solid level surface at least 12 inches (30 cm) from walls.
Ensure unit is as level as possible. In order to avoid damaging
the air compressor, do not incline the unit transversely or
longitudinally more than 10°.
TEMPERATURE. Ideal operating temperatures are between
50°F and 100°F (10°C and 37.C).
CAUTIO
N
Never operate in temperatures below 3F
(0°C)orabove104°F(40.0°C).
HUMID AREAS. In frequently humid areas, moisture may form in
the compressor and produce sludge in the lubricant, causing
running parts to wear out prematurely. Excessive moisture is
especially likely to occur if the unit is located in an unheated area
that is subject to large temperature changes. Two signs of
excessive humidity are external condensation on the compressor
when it cools down and a milky” appearance in petroleum
compressor lubricant. You may be able to prevent moisture from
forming in the compressor by increasing ventilation or operating
for longer intervals.
ATTACHMENTS ___________________________________
When attaching tools and accessories to your air compressor,
a
dhere to the following general guidelines. Contact customer
service for more information.
CAUTIO
N
If you will be using Ingersoll Rand “All-Season
Select” synthetic lubricant, all downstream
attachments must be compatible. Refer to the
following material compatibility list. If there are
incompatible materials present, or if there are
materials not included in the list, contact
customerservice.
Suitable:
Viton®, Teflon®, Epoxy (Glass Filled), Oil Resistant Alkyd,
Fluorosilicone, Fluorocarbon, Polysulfide, 2-Component Urethane,
Nylon, Delrin®, Celco, High Nitrile Rubber (Buna N. NBR more than
36% Acrylonitrile), Polyurethane, Polyethylene, Epichlorohydrin,
Polyacrylate, Melamine, Polypropylene, Baked Phenolics, Epoxy,
Modified Alkyds
indicates trademark of DuPont Corporation)
NotRecommended:
Neoprene, Natural Rubber, SBR Rubber, Acrylic Paint, Lacquer, Varnish,
Polystyrene, PVC, ABS, Polycarbonate, Cellulose Acetate, Low Nitrile
Rubber (Buna N. NBR less than 36% Acrylonitrile), EPDM, Ethylene
Vinyl Acetate, Latex, EPR, Acrylics, Phenoxy, Polysulfones, Styrene
Acrylonitrile (San), Butyl
GENERAL REQUIREMENTS. The att
achments, piping, fittings,
receiver tank, etc. must be certified safe for at least the
maximum working pressure of the unit. Use hard-welded or
threaded steel or copper pipes, cast iron fittings and hoses that
are certified safe for the units discharge pressure and
temperature. DO NOT USE PVC PLASTIC. Use pipe thread
sealant on all threads, and make up joints tightly to prevent air
leaks.
CONDENSATE DISCHARGE. Condensate must be disposed of
in accordance with local, state, and federal laws and regulations.
NOTE All com
pressed air systems generate
condensate which accumulates in any drain
point (e.g. tanks, filters, drip legs, aftercoolers,
dryers). This condensate contains lubricating
C
E
F
P
B
G
J
A
N
O
H
I
M
K
D
L
M
A TANK PRESSURE GAUGE
B LINE P
RESSURE GAUGE
C TANK
D RUBBER BUMPER
E SAFETY / RELIEF VALVE
F ON/OFF SWITCH
G MOTOR/PUMP
H INTAKE FILTER
I CYLINDER
J OIL DIPSTICK
K CASING COVER
L OIL DRAIN CAP
M TANK DRAIN
N PRESSURE REGULATOR KNOB
O QUICK CONNECT
P LIFTING HANDLE
2
http://air.ingersollrand.com
P1IU-A9
@ 90 PSI (6.2 bar) 4.3 CFM (125 l/min)
@ 135 PSI (9.3 bar) 3.2 CFM (90 l/min)
Seitenansicht 1
1 2 3 4 5 6 7 ... 31 32

Kommentare zu diesen Handbüchern

Keine Kommentare